CAUSE ANALYSIS AND TEST STUDY ON SOMEHAT LOWER STEAM TEMPERATURE FOR A 2008t/h CORNER TANGENTIAL FIRING BOILER

郑晓康,张传名,宋国良,周俊虎,曹欣玉,刘建忠,岑可法
DOI: https://doi.org/10.3969/j.issn.1002-3364.2004.11.010
2004-01-01
Abstract:Directing against the problem of somewhat lower steam temperature existing on a 2008t/h boiler of one power plant, the arrangement of burners in the boiler has been adjusted, increasing the heating surface area of rear panel reheater, carrying out thermal calculation and combustion adjustment test for the said boiler. The results of calculation and test show that the following conditions are most helpful to enhance the main steam temperature: (1) contamination factor in the furnace to be maintained at 0.35~0.45; (2) coefficient of excess air to be about 1.3; (3) the upswing angle of the burner to be 8°~16°; (4) burnoff air in upper level to be closed, and oxygen content to be maintained at low level(3.0%). By means of adjusting swing angle of the burners and the spray type desuperheater, the said problems of main steam and reheated steam have been solved, enhancing the safety and economic behavior in operation of the unit.
What problem does this paper attempt to address?