Numerical simulation on effect of burner tilting up angle on reheat steam temperature deviation for tangentially fired pulverized-coal boiler

Dengfeng TIAN,Qingyan FANG,Peng TAN,Cheng ZHANG,Gang CHEN,Lijin ZHONG,Dianping ZHANG,Guoqiang WANG
DOI: https://doi.org/10.11949/j.issn.0438-1157.20141829
2015-01-01
Abstract:The burner tilting up and the bias setting of AA tilting up angle was employed in order to reduce the temperature deviation of flue gas and reheat steam. The combustion processes in a 700 MW tangentially fired boiler with different burner tilting up angles were numerically simulated. The simulated results were fitted in with the measured data well. For greater burner tilting up angle, the swirling momentum moment in the furnace and the residual swirling momentum moment in the entrance of platen zone were reduced, while the flue gas deviation in the horizontal flue gas pass was lower. The bias setting of AA burner tilting up angle can reduce the flue gas residual swirling momentum moment of the entrance of platen zone considerably and lower the deviation of the flue gas temperature and velocity. The combustion tests showed that as an effective measures to reduce the temperature deviation of flue gas and reheat steam of this boiler, the burner tilting up for 11° and the bias setting of AA tilting up angle for 10° can reduce the temperature deviation of reheat steam from 20℃to about 4℃.
What problem does this paper attempt to address?