Cause analysis and solutions about slagging of 670 t/h boiler in Zhuozi Power Plant

Gong You-jun
Abstract:To solve the slagging problem of a 670 t/h boiler in Zhuozi Power Plant, combustion adjustment experiment were performed and the temperature field in burner region was measured by a thermocouple. The result shows that the distance between the coal ignition point and the burner nozzle is more than 1.0 m in the center area of the burner, and that is in the range of -0.1 m to +0.1 m in the secondary air area of the burner. By increasing outer secondary air box damper opening and primary air flow can lower the temperature in the burner region near the water wall and the slagging near the burner nozzle.