Investigation on Slagging Using Biased Secondary Air for Tangential Boiler

陈刚,丘纪华,郑楚光
DOI: https://doi.org/10.3969/j.issn.1674-7607.2004.01.002
2003-01-01
Abstract:In the view of aerodynamic fields and operating parameters in furnace, the slagging reason of tangentially fired boiler in operation and anti slagging measures are introduced in this paper. Especially, numerical simulations and field tests research the effect of using biased secondary air for slagging in furnace for 125MW and 660MW units. The result shows that the angle of biased secondary air should be less than 15°.