Simulation of Slagging Prevention Property of the Furnace with Deviated Secondary Air System

周昊,孙平,池作和,蒋啸,岑可法
DOI: https://doi.org/10.3321/j.issn:1006-8740.2002.04.009
2002-01-01
Abstract:The deflected secondary air system has been widely used in the large capacity utility boilers. In such a system, the lower secondary air is deflected to the waterwall and the upper secondary air and the overfire air are deviated to the opposite direction of the flow rotation direction in the furnace, in order to obtain the effect of slagging-prevention and decreasing the twisting residual at the exit of the furnace. Through the numerical methods, the slagging prevention property of a 600 MW utility boiler with a deflected second system was calculated on the basis of the simulation of flow field, temperature field, solid and gas combustion and the deposit growth under slagging conditions. The results illustrate that the numerical methods used in this paper is feasible and it can give reference to the design and operation of a high capacity utility boiler with deflected secondary air system.
What problem does this paper attempt to address?