Test and numerical simulation of multiphase dynamics in utility boiler with concentric firing system

Zuohe Chi,Luochan Shen,Jianjun Xia,Hao Zhou,Xiao Jiang
1997-01-01
Abstract:Concentric Firing System (CFS) has been used in several utility boilers, whose capacities are 125 MW and 300 MW. And fairly good results of combustion strength and water-wall slagging pretension are achieved. In this paper, large quantity of cold model test and numerical simulation were completed in model furnace with CFS. The measurement and simulation results, such as velocity field, diameter of actual flow and speed difference in exit of furnace, etc., were obtained. They can provide reference for design and retrofit of utility boilers.
What problem does this paper attempt to address?