Experimental Reseach on Cold Aerodynamic Characteristic in Hexagonal Arranged CWS Boiler

曹欣玉,丁宁,赵凯,周俊虎,黄镇宇,刘建忠,杨玉林,杨亮
DOI: https://doi.org/10.3969/j.issn.1674-7607.2004.02.005
2004-01-01
Abstract:The paper reports on study result on aerodynamic field in a high length-width ratio, large capacity CWS utility boiler through the method of hot simulation after amplifying combustor and adding furnace bottom wind. Through the experiments we get the changing methods of flow field inside the furnace, the velocity near the furnace wall and the velocity misalignment in the front wall airstreams. It is concluded that, for the furnace with a high length-width ratio, hexagonal arrangement could lead to a rational flow field, what's more, the counter-tangential arrangement of overfire air could reduce the velocity misalignment in the front wall airstreams evidently and the effluxion of in-furnace flow. Figs10, table 1 and refs 3.
What problem does this paper attempt to address?