Numerical Simulation of the Impact of Secondary Air for a Pant-Leg 300 MW Circulation Fluidized Bed Boiler

郑成航,程乐鸣,骆仲泱,王勤辉,施正伦,岑可法
DOI: https://doi.org/10.3785/j.issn.1008-973x.2010.04.021
2010-01-01
Abstract:Secondary air plays very important role in combustion for oxygen supplement and NOx control in a circulation fluidized bed (CFB) furnace.However the distribution of secondary air in the furnace becomes worse as the furnace is enlarged.Numerical simulation was performed to study the impacts of secondary air in the furnace of a pant-leg 300 MW CFB boiler.The flow fields of solids velocity and concentration were computed at different secondary air injecting velocity and direction using Fluent6.2.The distributions of solids velocity and concentration were given and analyzed at different location and cross-section in the furnace.The penetrability of secondary air was also analyzed.The simulation shows that the solids flow goes down in the middle of the furnace,and the distribution of solids concentration in the Z cross-section is uneven,which is similar to a combination of several core-annular flows.The solids concentration in the top of furnace is higher with the one.The secondary air can optimize the gas and solids flow fields in the furnace.The penetration of outboard secondary air injection is better than that of the inboard one.The simulation results can be referenced in the design and operation for a large CFB boiler.
What problem does this paper attempt to address?