Influence of closing-to-wall air on flow characteristics of a boiler's secondary-air-box: numerical simulation

Hongtao ZHANG,Jian GUAN,Ruimei LIU,Qing HU,Weijuan YANG,Zhihua WANG,Lichun QIU
DOI: https://doi.org/10.3969/j.issn.1002-3364.2017.04.077
2017-01-01
Abstract:Taking the secondary-air-box of a 300 MW unit boiler with front and rear wall opposed firing as the example,numerical simulation method was employed to investigate the effects of closing-to-wall air on air distribution and flow characteristics inside the secondary-air-box.The results show that,the flow rates of the side bumers were lower than that of the middle ones before the transformation.Once the closing-to-wall air jet was added,the flow rates of the side burners increased and became higher than that of the middle ones,and the uniformity of the air distribution turned better.The flue gas velocity at the burner exit section changed in the same rule.The closing-to-wall air rate was stable at about 6.57% in each case.Under rated load condition,the deviation of the burner flow rate was within 3% when adding 4% secondary air rate,which could still ensure the furnace stability.