RELATION BETWEEN THE VOLUME HEAT LOAD OF UPPER FURNACE AND THE FLUE GAS TEMPERATURE DIVIATION FOR TANGENTIAL FIRING BOILER

陈刚,郑楚光
DOI: https://doi.org/10.3321/j.issn:0258-8013.2002.11.032
2002-01-01
Abstract:Flue gas temperature deviation at the exit of furnace is investigated for large tangential firing boiler. Based on the mechanism analyses and operation parameters of combustion system, the new concept of volume heat load of upper furnace is introduced initiatively. For the 600MW, 300 MW, 200 MW units, the maximum values of volume heat load of upper furnace are given as much as 0.85106kJ/m3h, 0.95106kJ/m3h ,1.05106kJ/m3h. some measures of reducing flue gas temperature deviation are introduced based on the new concept,, such as shifting down position of tertiary air, tilting down upper group burner, shutting down or decreasing the top primary etc. The results of some boilers reform show that the measures are very effective.