BURST ANALYSIS OF HIGH TEMPERATURE RE-HEATER PIPE OF POWERSTATION

刘高杰,李希超,任相文
DOI: https://doi.org/10.3969/j.issn.1001-4012.2003.07.009
2003-01-01
Abstract:The burst of high temperature re-heater pipe of powerstation occured when it operating over 30000 hours. It causes a lot of enormous losses. This article researchs the cause of cracking by means of macroscopic inspection, mechanical property testing etc. It was found that the cracking is induced by the partial superheat and superpressure. We put forward a proposal for improving the management of this eguipment.
What problem does this paper attempt to address?