Analysis of Scaling on Absorber Wall of CFB-FGD System and Its Mechanism

ZHAO Xudong,XIANG Guangming,YAO Qiang,MA Chunyuan
DOI: https://doi.org/10.3321/j.issn:0438-1157.2006.02.031
2006-01-01
Abstract:An analysis of scaling on the inside wall of the Circulating Fluidised Beds Flue Gas Desulphurization (CFB-FGD) absorber and its mechanism was carried out. It was found that deposition and agglomeration mainly occurred in a circular high humidity area which was 4 to 5 meters above from the nozzles. Such factors affecting the deposition were studied, including system running conditions, tower makeup, nozzle size, in-tower flow and temperature profiles. The composition of the deposited materials was analysed. It was found that both the composition and the forming mechanism of scaling were far different from the wet FGD, and that scaling was caused mainly by wet ash which was easy to adhere to the wall, and secondly by CaCO_3 which reflected the important role of CO_ 2 in the scaling process. Finally, approaches to prevent scaling were proposed.For example,a specially designed multi-piped venturi scrubber was installed in order to increase the vertical velocity of the particles.
What problem does this paper attempt to address?