Analysis of Scaling on Gas-Gas Heater Surfaces of Wet Flue Gas Desulfurization Systems

ZHONG Yi,Xiang Gao,Wang Huo,WANG Hui-ting,Zhongyang Luo,Mingjiang Ni,CEN Ke-fa
DOI: https://doi.org/10.3321/j.issn:1000-6761.2008.02.023
2008-01-01
Abstract:Blocking problems of scaling formed in gas-gas heaters(GGH) are often encountered in the continuous operation process of domestic wet flue gas desulfurization(WFGD) systems.To find the causes,samples taken from GGH,gypsum byproduct and boiler fly ash were analyzed respectively with scanning electronic microscopy(SEM) for particles' surface morphologies,X-ray diffraction(XRD) for crystal structures and X-ray fluorescence(XRF) for element compositions.Results show that the scaling was caused by saturated gypsum slurry droplets that had not been removed completely by mist eliminators and was carried over to GGH,which subsequently covered by fly ash from flue gas.
What problem does this paper attempt to address?