Analysis of Blocking Reason on Gas-gas Heater of Dingzhou Power Plant's Flue Gas Desulfurization System

LI Yong,ZHANG Qian
DOI: https://doi.org/10.3969/j.issn.1672-6413.2011.06.066
2011-01-01
Abstract:To study the reason for blockage in gas-gas heater(GGH) of wet flue gas desulfurization system of Dinghou Power Plant,X-ray diffraction was used to analyze the crystal structures attached to GGH and measure the velocity of flue gas at the entrance and exit of demister.The results indicated that CaSO4·2H2O and CaSO4 were the main scale substances and fly ash was involved in the scaling process;Velocity of flue distributed unevenly at the entrance of demister.The maximal velocity was 16.6 m/s and minimal velocity was 0 m/s.Average velocity was 8.06 m/s and global velocity was high,so there made demisting efficiency down sharply.Therefore,the blockage reason of GGH attributes to the higher flue velocity of demister inlet which causes the drops flow along the demister and then entry into GGH.
What problem does this paper attempt to address?