Experimental Research on the CFB-FGD of Semi-Dry Process in Ambient Temperature in a Demo Plant

王晓芳,佟会玲,李定凯,李彦,程从明,陈昌和,徐旭常
DOI: https://doi.org/10.3969/j.issn.1674-7607.2004.03.025
2004-01-01
Abstract:The experimental research on the CFB-FGD of semi-dry process in ambient temperature were conducted in a demo plant of Tsinghua university. The designed flow rate of flue gas treated by the CFB-FGD demo plant was 20,000Nm~3/h. In order to achieve the internal circulation of solid particles, special structure was adopted within the absorber of the CFB-FGD.A series of experiments were carried out to investigate the influence of basic operating parameters such as approach-to-saturation temperature (ASAT), Ca/S ratio, solids concentration in the absorber, CaCl2 additive on the sulfur capture. The experimental dates show: under the conditions of the Ca/S range of 1.3 and the ASAT range of 7℃ the SO2 removal efficiency can reach 85%;In the same condition, with the CaCl2 added into lime slurry,the SO2 removal efficiency can reach 90%. The mechanism analysis of desulphurization process was also studied and the method to increase ion reaction time was introduced. Figs 6 and refs 7
What problem does this paper attempt to address?