Pilot Plant Study of Wet Slurry Jet Flue Gas Desulfurization

项光明,肖海涛,姚强,李定凯,张贞良,徐旭常
DOI: https://doi.org/10.3321/j.issn:1000-0054.2003.12.018
2003-01-01
Abstract:The performance of a wet slurry jet flue gas desulfurization (FGD) system was measured in a pilot plant in Shenyang, China. The results show that the absorbed SO_2 per unit volume of slurry is related exponentially to the slurry pH. An increased flue gas volumetric flow rate enhances the droplet surface renewal effect, an increased inlet SO_2 concentration enhances the mass transfer driving force, and an increased recycle slurry flux enhances the droplet agglomeration. The increased flue gas flow rate and inlet SO_2 concentration enhance the desulfurization reaction, while an increased gross inlet SO_2 flow rate reduces the desulfurization efficiency. Increases in the slurry flow rate increase the desulfurization efficiency, which illustrates the advantages of the wet slurry jet FGD.
What problem does this paper attempt to address?