Valve timing effect on the cooling performance of a 4 K pulse tube cooler

L.M Qiu,G Thummes
DOI: https://doi.org/10.1016/S0011-2275(02)00043-7
IF: 2.134
2002-01-01
Cryogenics
Abstract:Generally, a compressor together with a rotary valve system generates the pressure oscillation in GM-type cryocoolers. The timing of the rotary valve, which is one of the key operating parameters for cryocoolers, determines the relationship between intake and exhaust processes. A systematic investigation of valve timing effects on cooling performance of a two-stage 4 K pulse tube cooler (PTC) is reported. The experiments show that the optimization of valve timing can considerably improve the cooling performance for both stages. For the same PTC, a performance comparison for operation on different compressors with various input powers ranging from 0.5 to 6.0 kW is also presented.
What problem does this paper attempt to address?