Experimental research and finite element analysis on tubular joints of Hangzhou East Railway Station

Pang Yanfeng,Zhao Yang,Dong Shilin
DOI: https://doi.org/10.19701/j.jzjg.2013.07.018
2013-01-01
Abstract:The roof structure for the main building of Hangzhou East Railway Station adopts a long-span spatial steel truss supported by inclined elliptical steel columns with variable cross sections and inclined tubular lattice steel columns.Spatial tubular joints in this structure have complicated configurations.In order to investigate the structural behavior of the complex joints,to test whether their strengths meet the design requirements and to verify the reliability of the finite element model,experiments were carried out on several key joints located at the roof truss,the inclined lattice columns and the single-layer ellipsoid reticulated shell respectively.Followed by a brief introduction on the test joint design,loading device,loading procedure and measuring point layout scheme,the main experimental results and the corresponding finite element results were described.It is shown that,all test joints have good bearing capacity,the design of joints is safe and reliable,and the elasto-plastic nonlinear finite element analysis can simulate the bearing behavior of the test joints satisfactorily.
What problem does this paper attempt to address?