Experimental study of static behavior of Y-type cast-steel joint in west Nanchang Railway Station

Menglei WANG,An ZHOU,Gang SHI,Xianghua LIU
DOI: https://doi.org/10.3969/j.issn.1003-5060.2014.01.021
2014-01-01
Abstract:Through the full-scale test and finite element analysis of Y-type cast-steel joint in west Nan-chang Railway Station ,the stress performance of cast-steel joint under the two-way bending moment and axial force was studied .The stress values obtained by full-scale test were compared with those by finite element analysis to determine the stress distribution of the joint .The effect of central rainwater pipes on the bearing capacity of the joint and the effect of the bearing moment on the ultimate axial force of the joint were analyzed .The safety of the cast-steel joint was evaluated by using Von Mises yield criterion .It is show n that the results of the numerical simulation are reliable and the cast-steel joint has high safety under testing load .The presence of central rainwater pipe has little effect on the bearing capacity of the Y-type joint ,but the bending moment has a great effect on the ultimate axial force of the joint .
What problem does this paper attempt to address?