Experimental Study on Bearing Capacity of Beam-Column Pin Joints in Long-Span Steel Structure Under Heavy Load

Dayi Ding,Junzhu Linghu,Gang Shi,Qiuzhuan Fan,Yu Jia
DOI: https://doi.org/10.11784/tdxbz201505011
2015-01-01
Abstract:A multi-story industrial plant is steel frame structure. In the second floor,pin joints have been adopted for the connections between large-span steel truss of floor and steel columns. H-section steel was applied in upper and lower chords and web members. Pin joints were used to connect joint region with specific construction form of chords and web members to extending ear plates of columns. In order to achieve requirements of engineering design,the bearing capacity of this type of pin joint needed to be determined. According to design requirements and results of finite element simulation,four specimens of this type of connection were designed and used to conduct experimental analysis. The result illustrates that pin joints remain in elastic stage under design load,and when it reach failure stage,it still have good ductility. The bearing capacity of this joint meets the design demand and can be used as refer-ence for similar projects.
What problem does this paper attempt to address?