Analysis of a New H-section Beam to Rectangular Tube Column Connection

Zhao Wei,Tong Genshu,Guo Lixiang
2006-01-01
Abstract:High-frequency welded rectangular tube column has high production efficiency,high torsional and out-of-plane stiffness.Sometimes concrete may be filled into the tube to improve its capacity and behavior against local buckling. High-frequency welded rectangular tube column is more economic than the current welded H-section steel (variable cross-section) light industrial building .In order to increase bearing capacity of beam - to - column connection and reduce joint deformation,a new joint detail is proposed,of which column head was flushed with beam upper flange, partial column web was welded with U - steel,and extended U - steel has stiffener.Calculation shows that this connection has very high joint stiffness and strength,and may meet requirements of a rigid connection in terms of its stiffness and capacity.
What problem does this paper attempt to address?