Research on Key Joints Design of Mega Frame of the Shanghai Tower

DING Jiemin,LI Jiupeng,HE Zhijun
DOI: https://doi.org/10.14006/j.jzjgxb.2011.07.006
2011-01-01
Abstract:The Shanghai Tower adopts the lateral resisting system of mega frame-core-outrigger structure.Joints design is the key phase during design procedure of the mega frame.Firstly,the principles of the performance-based design of joints were introduced briefly.Secondly,the design of two typical joint of the mega frame,the joint of outrigger to super-column and the long bolt joint of the belt truss,were checked.The joint of outrigger to super-column bears bending moment and axial force,the stress state of which was very complicated.The reasonableness of simplified formula was verified by using finite element analysis.The results show that the simplified formula meets the project requirements and can be accepted as a check formula in the preliminary design.The long bolt joint of the belt truss which has a super-long length includes a large quantity of bolts,thick splice plates and thick member sections.According to finite element analysis,the performance and mechanical behavior of the joint are revealed and its reliability is verified too.The results show that the bolt joint has enough capacity under specific performance requirements.Terminal bolts transfer more force and intermediate bolts transfer little.With the increasing of loads,the nonhomogeneity of transfer force of bolts reduces.The mechanical property of members will be changed as the bolt joint has large length.