Failure Analysis of Stainless Steel Gate Valve in Ammonium Phosphate Solution

QIU Yan-Li,ZHANG Hong-He,YANG Zhen-Guo
2007-01-01
Abstract:The macro appearance,morphology and metallographic structure of stainless steel gate valve leaked in ammonium phosphate solution were observed by metallurgical microscope and scanning electron microscope (SEM). The photoelectric direct reading spectrometer,X-Ray fluorescence spectrometer and NHO-analyzer were used to analyze chemical composition of materials and particles deposited on the disc.The results show that the failure of gate valve is caused by electrochemical corrosion and scaling because of the wrong material and environment medium.Moreover,countermeasures are put forwarded on the research basis.
What problem does this paper attempt to address?