Failure Analysis on Corrosion of Refeed Valve Manhole Door in Circulating Fluidized Bed Boiler

Zhen‐Guo Yang
2008-01-01
Abstract:By means of optical spectrometer(OS),thermogravimetric analysis(TGA),X-ray diffraction(XRD),scanning electron microscope(SEM)and energy dispersive spectroscope(EDS),the corrosives and fracture face of the perforation of refeed valve manhole door in the petrol coke/coal fired FW circulating fluidized bed(CFB)boiler were studied.Finally,based on the analyses results it is shown that,the corrosion perforation was caused by the co-effect of corrosion and abrasion brought by the high S content corrosive particles,prevention methods and the suggestion that,the material of manhole door should be substituted from hard cast aluminum to Cr-Ni stainless steel,were put forward.
What problem does this paper attempt to address?