Failure analysis of heat exchange tubes in hydrogenation unit

Yan Liu,Yanpeng Qu,Feng Chang,Songling Li
DOI: https://doi.org/10.1016/j.engfailanal.2021.105718
IF: 4
2021-11-01
Engineering Failure Analysis
Abstract:The leakage failure of the austenitic stainless steel tubes in the hydrogenation unit of a petrochemical company was analyzed. The causes of the failure were investigated by visual examination, chemical compositions analysis of the tube, microscopic examination, metallographic examination and scale layer analysis. The results showed that the directly reason of the failure is pitting corrosion and stress corrosion cracking. We concluded that the improper heat treatment of the austenitic stainless tubes and existence of the corrosive substances including wet hydrogen sulfide and hydrogen chloride in the working medium, result in the occurrence of the corrosion, and the complex flowing conditions accelerate the corrosion process. Proposals were put forward in this paper.
engineering, mechanical,materials science, characterization & testing
What problem does this paper attempt to address?