Analysis of Cracking of Pressure Gauge Spring Tube for Hydrogenation Plant

Hu Lihong,Zhao Lin,Zheng Liqun
DOI: https://doi.org/10.3969/j.issn.1007-015X.2012.04.014
2012-01-01
Abstract:The spring tube installed in the stainless steel pressure gauge on the outlet line of HP heat exchanger in the hydrogenation plant of a refinery cracked.The macro observation,SEM and EDX examinations,energy spectrometry analysis,metallographic analysis,hydrogen content analysis and hardness test of failed samples show that the cracking of spring tube in the pressure gauge is mainly caused by high service temperature.In addition,as the Ni and Mo contents are out of specifications and austenitic stainless steel has higher content of super-saturated hydrogen,these hydrogen molecules can not be released and are concentrated in the stress-concentrated area in the top of oblate tube.The result shows that the cracking mechanism is sulfide stress corrosion cracking.Therefore,the hydrogen damage(i.e.SSCC) occurs in the wet hydrogen sulfide environment.The cracking can be controlled by selection of right material for pressure gauge,hydrogen examination of spring tube,control of water in service media and proper reduction of operating temperature,etc.
What problem does this paper attempt to address?