Study on Leakage Reasons of Gate Valve in Ammonium Phosphate Solution

QIU Yan-li,YANG Zhen-guo
DOI: https://doi.org/10.16630/j.cnki.1002-5855.2007.04.001
2007-01-01
Abstract:The gate valve which leaked in ammonium phosphate solution was characterized by metallurgical microscope,SEM to analyze macro appearance,micro morphology and metallographic structure.Also Photoelectric Direct Reading Spectrometer,X-Ray Fluorescence Spectrometer and NHO-analyzer were used to analyze chemical composition of materials and particles covered on the wedge disc.The results showed that the failure mode of gate valve is scale and corrosion.Moreover,countermeasures for solving the problem have been tentatively put forward.The analysis result provides the technological support to prevent the same accident.
What problem does this paper attempt to address?