The Shaking Table Test on a Prefabricated Integral Frame Shear Wall Structure with a New Prefabricated Floor

Weikang Jiang
2013-01-01
Abstract:The development of prefabricated building is an important measure to achieve building energy efficiency.In this paper,based on the rigid requirements of the floor in the plane,combined with the actual engineering,there is a shaking table test of the new three-story steel frame shear wall structure model of the precast floor without postcast surface layer.At the same time,the deformation of the surface on the floor of the new prefabricated assembly as a whole,and the performance to pass the horizontal seismic force is studied.The rigidity of the floor without pouring surface layer can ensure the integrity of the structure and the effective transmission of the horizontal force.This paper holds that the prefabricated floor without pouring surface layer can take the place of cast-in-place floor in areas with high seismic intensity.
What problem does this paper attempt to address?