Early Mitigation Measures for High Flux Reactor Loss-of-Coolant Accidents

Zhuang Wang,Gan Zhu,Heng Xie
DOI: https://doi.org/10.1115/icone29-91004
2022-01-01
Abstract:Abstract The thermal hydraulic characteristics of high flux research reactor (HFRR) are different from those of pressurized water reactor (PWR). Therefore, the emergency core cooling system of HFRR must be reconsidered and redesigned to ensure the core safety of HFRR in the event of loss-of-coolant accident (LOCA). This paper designs and analyses a set of mitigation measures for LOCA in the high flux research reactor. Relap5 is used for thermal hydraulic system analysis and breaks at three different sites are simulated. The primary coolant system includes four loops, each of which consists of a main pump, a heat exchanger and the corresponding pipes and valves. The three break sites are the main pump outlet, the main pump inlet and the heat exchanger inlet respectively. The core pressure, mass flow, coolant temperature, etc. in the transient process are studied and analyzed. And the responses of the mitigation measures during LOCA are organized and summarized. In this research, critical heat flux is calculated by Sudo correlation and the onset of nucleate boiling is calculated by Bergles-Rohsenow correlation. Through analysis, it can be found that the current mitigation measures can ensure the safety of core in the early stage of LOCA.
What problem does this paper attempt to address?