Effect of colloidal silica particles on subsurface damage of fused silica optics during CMP process

Zou Chunli,Xu Li,Kang Chengxi,Zhang Xin,Pan Guoshun
2017-01-01
Abstract:In this paper, the relationship between the surface defects characterization after CMP and the size of the SiO2 abrasive was investigated in detail. The combination of HF etching and optical surface profiler is used to detect and analysing the subsurface defects. Atomic force microscope (AFM) was used for measuring the surface morphology. The results indicate that, with the decrease of SiO2 abrasive size, obtaining smaller surface roughness and inducing much fewer subsurface defects. And the deeper etching, the rougher sub-surface. Keywords: Planarization, Chemical-mechanical Polishing, Fused silica, subsurface damage