Experimental Study on Wall Temperature Distribution Characteristics and Control Methods of Wall Temperature Uniformity in Tail Gas Catalytic Combustion

Chan Ha,Yi Jiao,Jiang Qin,Cong Wang,Sibo Wang,He Liu,Zekuan Liu,Fafu Guo
DOI: https://doi.org/10.2139/ssrn.4106416
2022-01-01
SSRN Electronic Journal
Abstract:The integrated auto-thermal reformer is a reactor for heating reforming reaction through catalytic combustion reaction. However, in the coupling process of the reactor, there is a local high temperature region, which produces a large thermal stress, and even affects the activity of reforming catalyst, leading to degradation and failure of the integrated reactor performance. In order to understand the cause and influence of local high temperature, and to find a way to eliminate local high temperature and provide temperature uniformity, experimental research is carried out in this paper. The results show that hydrogen can be ignited at 25°C in the presence of Pt/ Ce 0.5 Zr 0.5 O 2 catalyst. Hydrogen can react quickly when it comes into contact with the catalyst, so the temperature is highest at the reactor entrance and there is a marked local high temperature zone on the wall. Furthermore, when the inlet hydrogen to air volume ratio is 0.2, the reaction rate of hydrogen can reach 98%. By adjusting the arrangement of catalyst, the inlet velocity of reaction fluid and initial temperature, the wall temperature can become more uniform. Under Pt/Ce 0.5 Zr 0.5 O 2 catalyst, the optimum inlet temperature is 50 °C, and the hydrogen conversion rate is 90.7%.
What problem does this paper attempt to address?