Failure Analysis of Collecting Pipe Head Used in Ammonia Refrigerating System

Facai Ren,Bo Li,Xiaoying Tang
DOI: https://doi.org/10.1088/1757-899x/382/2/022101
2018-01-01
IOP Conference Series Materials Science and Engineering
Abstract:The head of a collecting pipeused in ammonia refrigerating system fractured during applications. The cause for head fracture was investigated by means of scanning electron microscope, optical microscope and chemical composition analysis. The results indicate that the welded joint has serious incomplete penetration defect. The fracture mode of collecting pipe head used in ammonia refrigerating system is brittle failure at low temperature.
What problem does this paper attempt to address?