Cracking Analysis on Water Cooling Wall Pipe in Power Plant

SHI Yue-li,GU Yong-qin,SUN Zhi
DOI: https://doi.org/10.3969/j.issn.0254-6051.2007.07.024
2007-01-01
Abstract:The microstructure and chemical composition of cracked water-cooling wall pipe used in power plant were analyzed,and its fracture was analyzed by SEM.The result shows that there are residual stress and inclusions in the structure at weld end between pipe and fin plate,and under working pressure the cracks initiate in weld end,then they propagate along tensile stress area and eventually result in fracture.