Ammonia injection method for SCR based on non-uniform inlet condition

Yinggui Zhou,Baosheng Jin
DOI: https://doi.org/10.13245/j.hust.160424
2016-01-01
Abstract:On the basis of the non‐uniform inlet boundary conditions which was more in line with the SCR(selective catalytic reduction) engineering practice ,a suitable CFD (computational fluid dynam‐ics) model was built based on a commercial 300 MW tangentially coal‐fired utility boiler′s SCR system in order to improve the uniform distribution characteristics of reducing agent in the tail flue on hybrid process .Measurements were conducted to analyze the trends and standard deviation of concentration distribution of reducing agent in ammonia different injection methods .Results show that the deviation of the NO flux in the entrance is relatively large with the maximum relative value close to 46 .7% . Without guide plates ,the velocity deviation factor on the E‐E cross section of bend Ch is 18 .13% , while this value could be reduced to 13 .61% by assembling 4 guide plates on the bend Ch .Under the uniform injection mode of vortex board device ,the standard deviation coefficient of the ammonia nitro‐gen ratio is 17 .52% .Using a non‐uniform injection method could reduce this coefficient to 15 .56% , which is an unsatisfactory promotion .However ,by combining the non‐uniform mode with ammonia injection grid ,it is observed that the standard deviation coefficient of ammonia nitrogen ration on the E‐E cross section could be reduced to 4 .72% ,w hile the influence on the velocity distribution is negli‐gible .All the results indicate that the non‐uniform mode with ammonia injection grid is a effective control mode for the SCR system .
What problem does this paper attempt to address?