Optimizing Flow Field in an SCR System of a 600 MW Power Plant: Effects of Static Mixer Alignment Style

Ye Dong,Wang Xiaoxiang,Wang Runxian,Gao Shujie,Liu Hui,Wang Haining
DOI: https://doi.org/10.1007/s42768-021-00082-z
2021-01-01
Waste Disposal & Sustainable Energy
Abstract:The fluid flow in a selective catalytic reduction (SCR) system of a 600 MW power station is optimized using the numerical simulation method in this work. Given that guide plates and straightening gratings are properly installed, the relative standard deviation ( C v ) of velocity related to the inlet of an ammonia injection grid (AIG) and catalysts satisfy the engineering demand of <15%, suggesting that a relatively uniform velocity field is obtained. The in-line arrangement of static mixers strengthens the disturbance of fluid, promoting the mixing of reductant NH 3 with flue gas. The NH 3 mole fraction C v value correlated to the inlet of catalysts drops to ca. 3.5%, which is lower than that in the cases when the mixers are aligned in a staggered style. These results indicate that a solid foundation is achieved for the effective abatement of NO x in practical applications.
What problem does this paper attempt to address?