Change of Ammonia Escape Rate and SO3 Conversion Rate of SCR Denitration in Full Load Range

ZHENG Fangdong,LI Wenhua,ZHAO Min,YANG Jianguo,YU Shangchang,LIU Xiushi,ZHAO Hong
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.160342
2017-01-01
Abstract:It is inevitable trend that the coal units should run with denitration in full load range and even in whole process. The effects of unit load and flue temperature on ammonia escape rate and SO3 conversion rate were studied on a 330MW subcritical unit with full load range experiments. And at the load of 165MW, the high pressure heaters were stopped to reduce the flue temperature merely. The NOx concentration of SCR inlet was controlled at 220mg/m3, and the denitration efficiency of SCR was controlled at 65% in full load range. With the load decreased, ammonia escape rate decreased first then increased at 165MW, and the SO3 conversion rate decreased linearly. When the flue temperature decreased from 319.5℃ to 288.3℃ with the high pressure heaters stopped at 165MW, the ammonia escape rate increased about one time, but it was still lower than which at 330MW. The ammonia escape rate was lower than the designed value of 3μL/L in full load range without any abnormal increasing. It was concluded that the load changing is not the main factor of ammonia escape rate increasing which could cause the air preheater blockage. According to the results, the SCR flue temperature limitation was adjusted from 300℃ to 290℃, to realize the SCR running in full load range. After the adjustment, the air preheater has been operated normally in about 1 year.
What problem does this paper attempt to address?