Mechanism and Influencing Factors of Overvoltage on Inverter-Fed Traction Motor Terminal

TONG Lai-sheng,WU Guang-ning,WEN Feng-xiang
DOI: https://doi.org/10.3969/j.issn.0258-2724.2005.05.023
2005-01-01
Journal of Southwest Jiaotong University
Abstract:Overvoltage is one of the main causes of damage in the isolation of inverter-fed traction motors.To solve this problem,the mechanism and influencing factors were analyzed with the transmission line theory and simulation on the equivalent circuit.The analyses show that overvoltage is a function of the rise time of the converter output pulse and the lengths of the traction motor cables,and that its magnitude can be as large as 1.9 times of the pulse voltage.The magnitude can be decreased to 1.1 times of the pulse voltage with a shunt R-C reactor.
What problem does this paper attempt to address?