Specimen Size Effect on Fracture Strength of Polysilicon Microcantilever Beam s

丁建宁,孟永钢,温诗铸
DOI: https://doi.org/10.3321/j.issn:1004-132X.2001.11.007
2001-01-01
Abstract:To investigate the specimen size influence on fracture strength and Young's modulus of microstructures, the validity of a novel, direct and convenient method for micromechanical property measurements by beam bending using a nanoindenter has been demonstrated. This method combines a very high load resolution with a nanometric precision in the determination of the microcantilever beam deflection. During deflection of microbeams, the influence of the indenter tip pushing into the top of the microbeams and the curvature across its width must be considered. The elastic deflection of a polysilicon microcantilever beam suggests that measured Young's modulus is 156 GPa(2.9%~6.3%).The result also shows that the rupture strengths of polysilicon beams reflect size effect on the effective volume and surface area of the specimens. The fracture toughness of polysilicon beams is as K C=1.62 MPa·m 1/2 .The sizes of defects that initiate fracture are in the range of 58~117 nm, which are the same magnitude of the surface roughness and slightly smaller than the grain size of polysilicon films of 100~200 nm.