Researches in the Flow Modeling of Critical Heat Flux in Bundle

陈军,吴小航,孙奇
DOI: https://doi.org/10.3321/j.issn:0258-0918.2002.04.004
2002-01-01
Abstract:The CHF experiments were carried out with 4×4 bundle of 9.5×1 rods and 1 000 mm heating length on Freon-12 thermal hydraulic test facility of BPNC. Under conditions of 1.59~2.73 MPa, 488~2 080 kg/(m 2·s) and -0.20~0.30 of the critical quality, 170 test data were collected, which are in accord with 206 CHF experimental data with 4×4 bundle in water under conditions of 9.9~16.2 MPa, 274~1 473 kg/(m 2·s) and -0.20~0.34 of the critical quality. Compared with CHF data between water and Freon-12, it was discovered that all of S.Y.Ahmad's compensation distortion model, Zhangzhenjie's model and Stevens-Kirby's model didn't fitted for bundle, with their error deviations beyond 20%. It was obvious that flow scale factor k was influenced by mass flow rate, pressure and the inlet quality. The correlation of flow scale factor k was then proposed, which improved the prediction precision of CHF modeling with the deviations within ±15% and the r.m.s error of 7.05%.
What problem does this paper attempt to address?