COMPARISON ANALYSIS OF CHF PARAMETRIC TRENDS IN VERTICAL TUBE AND 5 x 5 BUNDLE

Shumiao Wang,Jianqiang Shan,Bo Zhang,Xuemei Lang
2015-01-01
Abstract:Heat transfer is maximized at the CHF (critical heat flux) point and sharply reduced after that. CHF has a significant effect on the integrity, safety or economic efficiency of components and systems. Therefore, it's of vital importance to predict CHF accurately for given conditions. An accurate prediction of CHF requires a good understanding of physical mechanisms, parametric trends, as well as adequate experimental databases. A study on parametric trends of CHF has been carried out for water flow upward in vertical uniform heated round tubes. The study is based on the UO (University of Ottawa) database which is one of the largest tube CHF databases containing 78 data sets compiled from worldwide sources, more than 30,000 data points in all. The data in the range of conditions of practical interest is selected and unreliable data are removed according to the slice method, heat balance requirement and other screening criteria. The parametric trends of normalized CHF are explored with respect to variations in pressure, mass velocity and local quality. In addition, more than 2500 CHF experiment data points of uniform heated 5×5 bundle are picked out from Columbia University bundle CHF databases, which are used in comparison analysis of CHF trends in tube and bundle with respect to pressure, mass velocity and local quality obtained from subchannel code COBRA. It turns out that the two are largely consistent in terms of parametric trends. The research lay a solid foundation of better understanding, accurately predicting and enhancing CHF in tubes and bundle.
What problem does this paper attempt to address?