An experimental study on critical heat flux for low flow and low pressure of water in a hexagonal 7-rod bundle channel
Sen Chen,Leitai Shi,Huaqi Li,Da Li,Lixin Chen,Xiaofei Luo,Lei Zhu,Weitong Li,Xiaoyan Tian
DOI: https://doi.org/10.1016/j.pnucene.2024.105154
IF: 2.461
2024-03-17
Progress in Nuclear Energy
Abstract:This research explored novel experimental research on critical heat flux (CHF) in a hexagonal 7-rod bundle channel at low flow and low-pressure conditions. The heater rod in the experiment was composed of Inconel-625 alloy and the heated length was 390 mm, and the diameter was 37.2 mm. The experimental parameters of inlet temperature, outlet pressure as well as mass flux ranged from 39.7–71.7 °C, 130–197 kPa and 32.3–109.4 kg m 2 s −1 , respectively. More significantly, the influence of temperature, outlet pressure and mass flow on exit gas quality and CHF were investigated. It was found that CHF simultaneously increased with the rise of the mass flux and outlet pressure, but decreased with the drop of inlet temperature. Additionally, the exit quality increased along with the rise of inlet temperature and outlet pressure, but decreased with the increase of mass flux. Moreover, the CHF data measured in this experiment were also compared with the predicted results of several empirical correlations. The results indicated that the general correlations underestimated the experimental values, and there is a significant relative error between the look up table and the experimental values. Finally, an empirical correlation was developed to predict the CHF of the 7-rod bundle channel and showed that the proposed correlation could predict experimental results well, with a relative error of within ±10%.
nuclear science & technology