Reconsideration of the Design Method of Microcomputer-Based Main Protection for Large Hydro-Generator

王维俭,桂林,王祥珩,孙宇光
DOI: https://doi.org/10.3969/j.issn.1674-3415.2002.09.001
2002-01-01
Abstract:The design method of microcomputer-based main protection for large hydro-generator continues to use the method of the analog type protection.The main protection for S/C in a large hydro-generator is habitually configured with one or two sets of longitudinal differential relay and one or two sets of transverse differential relay.The sensitivity of longitudinal differential protection is checked by the S/C current at generator terminal,and the checkout of the sensitivity of transverse differential protection is abandoned without the availability of the calculation method of the internal faults of stator winding.The above design method doesn't really assure all kinds of internal faults of stator winding are tripped by two sets of protection.The popular practice that different types of hydro-generators with similar capacity and different winding construction use the same disposition of main protection may lead to harmful results in operation.