Study of Phase Shifting Mechanism of Inertance Tube at Low Temperatures

B. Wang,L. Y. Wang,J. K. Zhu,J. Chen,Z. P. Li,Z. H. Gan,L. M. Qiu
2012-01-01
Abstract:The inertance tube is widely used as phase shifter at ambient temperature in high frequency pulse tube cryocoolers, but it is difficult to obtain a comparatively large phase shift when there is a smaller acoustic power at the inertance tube inlet. However, inertance tube at cryogenic temperature, so called cold inertance tube, can provide a solution to this difficulty. Based on the transmission line theory by introducing real-gas properties of helium, the operating pressure, pressure ratio and reservoir volume, the performance of inertance tube at different temperatures are studied. The results indicate that the cold inertance tube can provide a better phase angle even with a smaller acoustic power. The phase angle increases with the decrease of temperature and pressure ratio. For the convenience of design, the charts of inertance tube working at different temperatures and dimensions are also provided in this paper. INTRODUCTION Pulse tube cryocoolers (PTCs) with no moving parts at the cold end have been studied intensively for many years for their advantages such as compact structure, high reliability and long life. Radebaugh’s1,2 researches indicate the losses in regenerator are minimized when the amplitude of the mass flow is minimized for a given acoustic power, which requires that the mass flow and pressure are in phase near the midpoint of the regenerator. To achieve the optimal phase relation in a PTC requires that the mass flow lags the pressure by about 30° at the cold end of the regenerator. The orifice3, double inlet valve4 and inertance tube5,6 are the three main phase shifters of PTCs. Among the three phase shifters, the inertance tubes, which rely on the inertia of the oscillating working gas in a long thin tube to produce a proper phase shift that the pressure oscillation leads the mass flow, make it possible to keep the pressure and mass flow in phase at the midpoint of the regenerator. The inertance tubes can also avoid the DC flow, making the performance of cryocoolers more stable, and it is now widely used in the high frequency PTCs. In ideal cases, the cooling power at the cold end of the pulse tube is equal to the acoustic power at the hot end of the pulse tube7, so inertance tubes can provide enough phase at large cooling powers for high frequency PTCs8-10. However, it is difficult for an inertance tube to produce a comparatively large phase shift in small cooling power PTCs due to the small acoustic power at the inlet of the inertance tube. 169 Cryocoolers 17, edited by S.D. Miller and R.G. Ross, Jr. ©¶International Cryocooler Conference, Inc., Boulder, CO, 2012 P# 018 2 The inertia of the inertance tube increases with the density of the working gas, which enhances the phase shift of the inertance tube. An inertance tube working at low temperatures, a so called cold inertance tube, can provide a solution to the difficulty of a small phase shift at small cooling powers for high frequency PTCs11-14. In this paper, a calculation analysis method based on the transmission line theory and including real-gas properties for simulating a cold inertance tube is introduced. The influences of operating pressure, pressure ratio and reservoir volume on the performance of inertance tubes at different temperatures are studied. The results indicate that the cold inertance tube can provide a larger phase angle even with a smaller acoustic power. The phase angle increases with the decrease of the temperature and pressure ratio. For the convenience of design, the charts of inertance tube working at different temperatures and dimensions are also provided. THEORETICAL ANALYSES Transmission Line Theory Based on the fluid network theory15, a transmission line theory model is adopted to calculate the phase shift of inertance tubes. The reliability of this model has been experimentally verified by Radebaugh16,17. Figure 1 shows the schematic of an inertance tube with a length of L and a reservoir. According to the transmission line theory model, the complex impedance of a terminated transmission line of length L is given by: (1) Where Z0(D) is the complex characteristic impedance of inertance tube, ζ (D) is the complex propagation function or wave number of the inertance tube, and Zr is the impedance of the reservoir, and the expressions for them are:
What problem does this paper attempt to address?