Leakage Effect Analysis on the Performance of a Cylindrical Adjustable Inertance Tube

Wenjie Zhou,John M. Pfotenhauer,Xiaoqin Zhi
DOI: https://doi.org/10.1016/j.cryogenics.2018.03.004
IF: 2.134
2018-01-01
Cryogenics
Abstract:The inertance tube plays a significant role in improving the performance of the Stirling type pulse tube cryocooler by providing the desired phase angle between the mass flow and pressure wave. The phase angle is highly depended on the inertance tube geometry, such as diameter and length. A cylindrical threaded root device with variable thread depth on the outer screw and inner screw creates an adjustable inertance tube whose diameter and length can be adjusted in the real time. However, due to its geometry imperfectness, the performance of this threaded inertance tube is reduced by the leaks through the roots between the two screws. Its phase angle shift ability is decreased by 30% with the leakage clearance thickness of 15.5 mu m according to both the theoretical prediction and the experimental verification.
What problem does this paper attempt to address?