Impedance Measurements of Inertance Tubes at High Frequency and Pressure

M. A. Lewis,R. Taylor,R. E. Bradley,R. Radebaugh,G. Grossman,Z. Gan
DOI: https://doi.org/10.1063/1.2908457
2008-01-01
Abstract:Previously measured and calculated impedances of inertance tubes were compared at frequencies below 70 Hz and average pressures below 3 MPa. In this paper we present similar comparisons for frequencies up to 150 Hz and average pressures up to 3.5 MPa. Measurements were made on inertance tube diameters from 1.0 mm to about 3.0 mm, as well as on a double diameter arrangement. Pressure ratios were varied from 1.1 to 1.45, and acoustic powers were varied up to about 80 W. In these measurements the use of higher frequencies has the potential of reducing the size of both the pressure oscillator and the cold finger for a given refrigeration power. The smaller cold finger also leads to faster cool-down. In these experiments, flow at the entrance to the inertance tube was determined from measurements of the calibrated pressure drop through a transfer line from the compressor. The wide range of frequencies and acoustic powers covered in these measurements enable us to separate the effects of compliance and inertance in the comparisons with a transmission line model.