The Study on a Gas-Coupled Two-Stage Stirling-Type Pulse Tube Cryocooler
X. L. Wu,L. B. Chen,X. S. Zhu,C. Z. Pan,J. Guo,J. J. Wang,Y. Zhou
DOI: https://doi.org/10.1088/1757-899x/278/1/012146
2017-01-01
IOP Conference Series Materials Science and Engineering
Abstract:A two-stage gas-coupled Stirling-type pulse tube cryocooler (SPTC) driven by a linear dual-opposed compressor has been designed, manufactured and tested. Both of the stages adopted coaxial structure for compactness. The effect of a cold double inlet at the second stage on the cooling performance was investigated. The test results show that the cold double-inlet will help to achieve a lower cooling temperature, but it is not conducive to achieving a higher cooling capacity. At present, without the cold double-inlet, the second stage has achieved a no-load temperature of 11.28 K and a cooling capacity of 620 mW/20 K with an input electric power of 450 W. With the cold double-inlet, the no-load temperature is lowered to 9.4 K, but the cooling capacity is reduced to 400 mW/20 K. The structure of the developed cryocooler and the influences of charge pressure, operating frequency and hot end temperature will also be introduced in this paper.