Monitoring Model for Ash Fouling on Semi-radiation Heating Surface of a 600 MW Supercritical Boiler

XU Ligang,HUANG Yaji,YUE Junfeng,CHEN Bo
DOI: https://doi.org/10.3969/j.issn.1674-7607.2015.11.002
2015-01-01
Abstract:To realize monitoring of ash fouling status on heating surface of coal-fired boilers,a monitoring model was established by taking the semi-radiation heating surface of a 600 MW supercritical boiler as the research object,and by using the ash fouling rate as the monitoring indicator,based on which a method for calculation of the flue gas temperature in high-temperature region was proposed,considering the dynamic characteristics of the boiler during variable load operation,while the lumped parameter dynamic correction model was adopted,so as to study the variation tendency of ash fouling on the semi-radiation heating surface during stable and variable load operation.Results show that the model for stable load operation can satisfy the monitoring requirement of ash fouling;whereas the calculation results obtained by the model for variable load operation is still affected by the load variation,even if the influence of load variation has already been considered.
What problem does this paper attempt to address?