Influence of cofiring high sodium coal on slagging in furnace of a 660 MW unit ultra-supercritical boiler

Yonggang ZHOU,Zhiliang XUE,Jianqiang CHEN,Pei LI,Zifu SHI
DOI: https://doi.org/10.3969/j.issn.1002-3364.2017.07.038
2017-01-01
Abstract:To alleviate the slagging in furnace of boiler firing high sodium coal, coals with weak fouling ability were co-burned. This paper discussed the calibration of temperature measurement system based on color CCD temperature detection system, and studied the influence of defocus and exposure time on temperature measurement accuracy by blackbody furnace. The flue temperature at furnace outlet of a 660 MW unit ultra-supercritical boiler was measured when burning blended Shenhua coal. The changing of furnace outlet temperature with furnace soot-blowing and the temperature rise rate at furnace outlet were also obtained under different blending schemes. Furthermore, a method was put forward for monitoring the furnace blending at fixed load. The results show that, the maximum deviation of the temperature measurement system is within 1.48% within the range from 950℃o t 1250℃, which iswithin engineering permissible error range. The temperature change and rise rate of furnace outlet of the blending scheme 4, 5 are obvious higher than that of the scheme 1, 2 and 3, which illustrates that the higher blending ratio of Shenhua coal, the more serious of slagging in the furnace, and the ratio should be less than 80%. When running in full load condition, the boiler should put 5 coal mills into operation, of which, mill A taking in Baoli coal, mill B to mill E taking in Shenhua coal, and the time interval of furnace soot-blowing is 15 h.
What problem does this paper attempt to address?