Effect of Coal Reburning and Injected Calcium on Fouling and Slagging Characteristics in Shenhua Coal Combustion

YU Hai-miao,CAO Xin-yu,ZHOU Jun-hu,LI Zhi,ZHOU Zhi-jun,LIU Jian-zhong,CEN Ke-fa
DOI: https://doi.org/10.3785/j.issn.1008-973x.2006.07.019
2006-01-01
Abstract:Shenhua coal was burned in the conditions of no reburning,reburning and reburning with injected calcium in 2.11 MW boiler with four-cornered combustor to study the fouling and slagging characteristics with coal reburning and injected calcium.Macroscopical phenomenon description,scanning electron microscope(SEM) analysis,electronic probe and X-ray diffraction(XRD) analysis were used to analyze the phenomena of fouling and slagging in the main combustion zone,reburning zone and burned zone,with emphasis on the difference and its reason in reburning zone.The results showed that the characteristics of fouling and slagging under condition of reburning did not remarkably change compared to no reburning,however,the reburning with injected calcium was distinctly deteriorated.Fe and Si were important factors for the fouling and slagging of Shenhua coal,and Ca,Si and Fe were prominent factors in the reburning with injected calcium.
What problem does this paper attempt to address?