Adjustment on reheat steam temperature for a 660 MW double-reheat boiler
Lin WANG,Bo YANG,Jinghui GAO,Yafu ZHANG,Zhidan ZHAO,Hongyu WANG,Yingqi MENG
DOI: https://doi.org/10.3969/j.issn.1002-3364.2017.08.091
2017-01-01
Abstract:The reheat steam temperature of China's firstly built double-reheat boiler is sharply lower than the design value. To solve this problem, the quality of coal as fired and the heat absorption capacity of the boiler heating surface was analyzed. Moreover, the flue gas recirculation thermal control scheme was improved. On this basis, the comprehensive temperature improvement scheme was proposed, including optimizing the coal mill combination type, regulating the burner elevation angle, increasing the over fired air volume, improving the soot-blower's putting-in-service mode and adjusting the flue gas recirculation amount. Furthermore, the condition test to explore the effect of burner's swinging angle and flue gas recirculation fan speed on temperature of the first reheat and second reheat steam were carried out. After debugging optimization , the reheat steam temperature of the boiler can reach 610~620℃at high load and 590~590℃ at low and medium loads, which are similar with the design value, indicating the problem of low reheat steam temperature was solved well. The debugging experience has project reference value for subsequent similar units.